Resuscitation
Volume 37, Issue 3 , Pages 149-152, June 1998

The effect of rescuer fatigue on the quality of chest compressions

  • F.Javier Ochoa

      Affiliations

    • Intensive Care Unit, San Millán Hospital, c/Autonomı́a 3, 26004 Logroño, La Rioja, Spain
    • Corresponding Author InformationCorresponding author. E-mail: eugenianfm26@smail.ocefss.ucm.es
  • ,
  • E Ramalle-Gómara

      Affiliations

    • Epidemiology and Health Promotion Service of La Rioja's Governement, La Rioja, Spain
    • Research Support Unit in La Rioja, La Rioja, Spain
  • ,
  • V Lisa

      Affiliations

    • Emergency Room, San Millán Hospital, c/Autonomı́a 3, 26004 Logroño, La Rioja, Spain
  • ,
  • I Saralegui

      Affiliations

    • Intensive Care Unit, San Millán Hospital, c/Autonomı́a 3, 26004 Logroño, La Rioja, Spain

Received 20 January 1998; received in revised form 24 April 1998; accepted 30 April 1998.

Abstract 

Objective: The aim of this study was to evaluate the influence of rescuer fatigue on the quality of chest compressions and the influence of the rescuer's gender, age, weight, height or professional status on the reduction of quality of chest compressions caused by fatigue. Material and methods: The study was carried out with the Laerdal Skillmeter™ Resusci Anne® manikin. The participants were doctors and nurses who work in the Intensive Care and Emergency departments, with an age ranging from 25 to 45 years and trained in cardiopulmonary resuscitation (CPR). Statistical analysis of results includes analysis variance and three models of multiple linear regression. Results: Thirty-eight people took part in the experiment; 20 (52.6%) were females; 15 (39.5%) staff physicians, 15 (39.5%) nurses and eight residents. Mean age was 34.1 years (SD=4.1). We found a significant reduction in correct compression performance over the course of time: in the first minute 79.7%, in the second 24.9%, in the third 18%, in the fourth 17.7% and in the last minute 18.5%. There were no differences related to the rescuer's gender or profession. The median interval until rescuers appreciated the effect of the fatigue on chest compressions quality was 186 s (SD=84.1); that appreciation was not influenced by gender, age, weight, height or profession. There were no differences in the percentage of correct compressions related to gender (P=0.07), insufficient sternal depression (P=0.23) or total number of compressions in the first minute. Discussion: A decrease of compressions quality after the first minute of CPR is produced. This effect does not depend on gender, age, weight, height or rescuer's profession and it is not adequately perceived by the person who performs the chest compressions.

Keywords:  Cardiopulmonary resuscitation, Cardiac massage, Rescuer fatigue, Manikin

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0300-9572(98)00057-4

Resuscitation
Volume 37, Issue 3 , Pages 149-152, June 1998