Resuscitation
Volume 81, Issue 4 , Pages 404-409 , April 2010

Monitoring in resuscitation: Comparison of cardiac output measurement between pulmonary artery catheter and NICO

  • Mªjosé Carretero

      Affiliations

    • Department of Anaesthesiology, Critical Care and Pain Management, Hospital Clínic, Universitat de Barcelona, Villarroel 170, C/Mina 47, ático 1, 08906 L’Hospitalet del Llobregat, Barcelona, Spain
    • Corresponding Author InformationCorresponding author. Tel.: +34 932275558; fax: +34 932279184.
  • ,
  • Jaume Fontanals

      Affiliations

    • Department of Anaesthesiology, Critical Care and Pain Management, Hospital Clínic, Universitat de Barcelona, Villarroel 170, C/Mina 47, ático 1, 08906 L’Hospitalet del Llobregat, Barcelona, Spain
  • ,
  • Mercé Agustí

      Affiliations

    • Department of Anaesthesiology, Critical Care and Pain Management, Hospital Clínic, Universitat de Barcelona, Villarroel 170, C/Mina 47, ático 1, 08906 L’Hospitalet del Llobregat, Barcelona, Spain
  • ,
  • Mªjosé Arguis

      Affiliations

    • Department of Anaesthesiology, Critical Care and Pain Management, Hospital Clínic, Universitat de Barcelona, Villarroel 170, C/Mina 47, ático 1, 08906 L’Hospitalet del Llobregat, Barcelona, Spain
  • ,
  • Julia Martínez-Ocón

      Affiliations

    • Department of Anaesthesiology, Critical Care and Pain Management, Hospital Clínic, Universitat de Barcelona, Villarroel 170, C/Mina 47, ático 1, 08906 L’Hospitalet del Llobregat, Barcelona, Spain
  • ,
  • Ana Ruiz

      Affiliations

    • Department of Anaesthesiology, Critical Care and Pain Management, Hospital Clínic, Universitat de Barcelona, Villarroel 170, C/Mina 47, ático 1, 08906 L’Hospitalet del Llobregat, Barcelona, Spain
  • ,
  • José Rios

      Affiliations

    • Laboratory of Biostatistics & Epidemiology (Universitat Autonoma de Barcelona), Statistics and Methodology Support Unit, IDIBAPS, (Hospital Clinic), Barcelona, Spain

Received 8 September 2009 ,Revised 27 November 2009 ,Accepted 14 December 2009.

References 

  1. Steen S, Liao Q, Pierre L, Paskevicius A, Sjoberg T. Evaluation of LUCAS, a new device for automatic mechanical compression and ative decompression resuscitation. Resuscitation. 2002;55:285–299
  2. Rubertsson S, Karsten R. Increased cortical cerebral blood flow with LUCAS; a new device for mechanical chest compression during experimental cardiopulmonary resuscitation. Resuscitation. 2005;65:357–363
  3. Botero M, Kirby D, Lobato E, Staples E, Gravenstein N. Measurement of cardiac output before and after cardiopulmonary bypass: comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing. J Cardiothorac Vasc. 2004;18:563–572
  4. Gudipati C, Weil M, Bisera J, Deshmuckh H, Rackow E. Expired carbon dioxide: a non invasive monitor for cardiopulmonary resuscitation. Circulation. 1988;77:234–239
  5. Kolar M, Krizmaric M, Klemen P, Grmec S. Partial pressure of end-tidal carbon dioxide successful predicts cardiopulmonary resuscitation in the field: a prospective observational study. Crit Care. 2008;12:R115
  6. Mally S, Jelatancev A, Grmec S. Effects of epinephrine and vasopressin on end-tidal carbon dioxide tension and mean arterial blood pressure in out-of-hospital cardiopulmonary resuscitation: an observational study. Crit Care. 2007;11:R39
  7. Ng JM, Chow MY, Ip-Yam PC, Goh MH, Agasthian T. Evaluation of partial carbon dioxide rebreathing cardiac output measurement during thoracic surgery. J Cardiothorac Vasc Anesth. 2007;21:655–658
  8. Van Heerden PV, Baker S, Lim SI, Weidman C, Bulsara M. Clinical evaluation of the noninvasive cardiac output (NICO) monitor in the intensive care unit. Anaesth Intens Care. 2000;28:427–430
  9. Osterlund B, Gedeon A, Krill P, Johansson G, Reiz S. A new method of using gas exchange measurements for the noninvasive determination of cardiac output: clinical experiences in adults following cardiac surgery. Acta Anaesthesiol Scand. 1995;39:727–732
  10. Binder JC, Parking WG. Noninvasive cardiac output determination: comparison of a new partial-rebreathing technique with thermodilution. Anaesth Intens Care. 2001;29:19–23
  11. Tachibana K, Imanaka H, Miyano H, Takeuchi M, Kumon K, Nishimura M. Effect of ventilatory setting on accuracy of cardiac output measurement using partial CO2 rebreathing. Anesthesiology. 2002;96:96–102
  12. Odenstedt H, Stenqvist O, Lundin S. Clinical evaluation of a partial CO2 rebreathing rechnique for cardiac output monitoring in critically ill patients. Acta Anaesthesiol Scand. 2002;46:152–159
  13. Stetz CW, Miller RG, Kelly GE, Raffin TA. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis. 1982;126:1001–1004
  14. Jaffe MB. Partial CO2 rebreathing cardiac output-operating principles of the NICO system. J Clin Monit. 1999;15:387–401
  15. Halperin HR, Paradis N, Ornato JP, et al. Cardiopulmonary resuscitation with a novel chest compression device in a porcine model of cardiac arrest. JAAC. 2004;44:2214–2220
  16. Timerman S, Cardoso LF, Ramires JAF, Halperin H. Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest. Resuscitation. 2004;61:273–280
  17. Casner M, Andersen D, Isaacs SM. The impact of a new CPR assit device on rate of return of spontaneus circulation in out-of-hospital cardiac arrest. Prehospital Emergency Care. 2005;9:61–67
  18. Swanson M, Poniatowski M, O’Keefe M, Shedd JG. Effect of a CPR assist device on survival to emergency department arrival in out of hospital cardiac arrest. Circulation. 2005;112:1006
  19. Lin LI. Assay validation using the concordance correlation coefficient. Biometrics. 1992;48:599–604
  20. Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989;45:255–268
  21. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–310
  22. Morley PT. Monitoring the quality of cardiopulmonary resuscitation. Curr Opin Crit Care. 2007;13:261–267[review]
  23. Mathews L, Singh RK. Cardiac output monitoring. Ann Card Anaesth. 2008;11:56–68
  24. Axelsson C, Karlsson T, Axelsson AB, Herlitz J. Mechanical active compression-decompression cardiopulmonary resuscitation (ACD-CPR) versus manual CPR according to pressure of end tidal carbon dioxide (P(ET)CO2) during CPR in out-of-hospital cardiac arrest (OHCA). Resuscitation. 2009;80:1099–1103
  25. De Waal EE, Wappler F, Buhre WF. Cardiac output monitoring. Curr Opin Anaesthesiol. 2009;22:71–77[review]
  26. Kieback AG, Borges AC, Schink T, Baumann G, Laule M. Impedance cardiography versus invasive measurements of stroke volume index in patients with chronic heart failure. Int J Cardiol. 2009;
  27. Bayram M, Yancy CW. Transthoracic impedance cardiography: a noninvasive method of hemodynamic assessment. Heart Fail Clin. 2009;5:161–168[review]
  28. Neuranter A, Nysæther J, Kramer-Johansen J, et al. Comparison of mechanical characteristics of the human and porcine chest during cardiopulmonary resuscitation. Resuscitation. 2009;80:463–469
  29. Levy RJ, Chiavacci RM, Nicolson SC, et al. An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children. Anesth Analg. 2004;99:1642–1647

 A Spanish translated version of the summary of this article appears as Appendix in the final online version at doi:10.1016/j.resuscitation.2009.12.021.

PII: S0300-9572(10)00006-7

doi: 10.1016/j.resuscitation.2009.12.021

Resuscitation
Volume 81, Issue 4 , Pages 404-409 , April 2010